Bry-Air MiniPAC MP-2700 Desiccant Dehumidifier – 2700 CFM, 460V 3-Phase
MP-2700 MiniPAC Desiccant Dehumidifier — 2700 CFM Large-Scale Industrial Moisture Control with PLC Controls and MODBUS Connectivity
The Bry-Air MiniPAC MP-2700 is the largest unit in the MiniPAC series, rated at 2,700 CFM process airflow with an 840 CFM reactivation circuit and a 42 kW heater bank — built for large industrial facilities where refrigerant dehumidification is not viable due to low operating temperatures, extremely high moisture loads, or humidity targets below 30% RH that refrigerant equipment cannot sustain. Unlike smaller MiniPAC units, the MP-2700 includes a touch-screen PLC with MODBUS RS485 communication, enabling integration with building management systems and automated process control environments. It operates on 460V 3-phase power at 61 full-load amps and is designed for continuous 24/7 duty in demanding industrial process environments.
MP-2700 Desiccant Rotor, Heater Bank, and PLC Control System
- 2,700 CFM process airflow at 1.26" wc (32 mm) external static — largest MiniPAC process airflow rating; handles very large manufacturing floors, warehouse zones, and multi-room industrial complexes requiring continuous high-volume moisture extraction
- 840 CFM reactivation airflow at 0.98" wc (25 mm) external static — proportionally larger reactivation circuit than smaller MiniPAC units; 840 CFM of warm, humid exhaust must be ducted to the building exterior
- 42 kW heater bank with SSR (solid-state relay) control — solid-state relay switching eliminates the mechanical wear and contact erosion of electromechanical contactors; provides precise heater staging for consistent reactivation temperature
- Desiccant rotor with stainless steel flange and edge-hardened media — edge hardening extends rotor media life in high-dust or high-particulate intake environments; stainless steel flange resists corrosion during field washing
- Touch-screen PLC with MODBUS RS485 connectivity — enables remote monitoring and control integration with building automation systems, DCS platforms, or SCADA systems; reduces on-site operator intervention in automated facilities
- 3 HP / 2.2 kW process motor; 1.5 HP / 1.1 kW reactivation motor — independently powered process and reactivation fans allow the unit to maintain airflow balance across both circuits
- 460V / 3-phase / 60Hz at 61 full-load amps — requires a dedicated 3-phase circuit with appropriate breaker and wire gauge for 61 FLA; consult a licensed industrial electrician for circuit sizing
- Independent pressure switches and temperature displays — separate monitoring of process and reactivation circuits allows fault isolation without shutting down the entire unit for diagnostic checks
- Reactivation safety thermostat — protects the 42 kW heater bank from overtemperature during sustained continuous operation
- Compact self-contained design — unit dimensions 1,227 × 1,156 × 830 mm (L × W × H); process inlet duct 577 × 267 mm; reactivation outlet collar Ø 197 mm
MP-2700 Applications: Large Industrial Plants, Lithium Battery Manufacturing, Power Generation, and Archival Storage
Lithium battery and electronics manufacturing facilities are among the most demanding desiccant dehumidifier applications — lithium battery cell assembly requires relative humidity below 1% RH in dry rooms, a target no refrigerant equipment can approach. The MP-2700 handles the airflow volumes required for large dry room environments at the process scale of industrial battery production. Chemical processing plants and pharmaceutical bulk API manufacturing areas require continuous low-humidity conditions across large process floors where refrigerant equipment's temperature sensitivity and humidity floor limitations disqualify it. Power generation facilities use large desiccant units to protect turbines, generators, and HRSG systems from corrosion during layup and standby — periods when the equipment is at ambient temperature and refrigerant dehumidifiers cannot operate at low-humidity setpoints. Museums and archival facilities with large collection storage areas, where tight humidity control across seasonal temperature swings is required, specify the MP-2700 where smaller MiniPAC units are under-capacity for the space volume.
Desiccant at 2700 CFM: MODBUS Integration, 3-Phase Power, and Ducting Requirements
At 2,700 CFM, the MP-2700 is sized for integration into building management systems rather than standalone operation — its MODBUS RS485 interface allows the unit to receive setpoint commands and report operating status to a central BAS or SCADA platform. This is particularly relevant in pharmaceutical GMP environments, cleanroom facilities, and automated manufacturing plants where humidity must be logged continuously for process validation and regulatory compliance. The 840 CFM reactivation exhaust must terminate at the building exterior with a duct system rated for the 0.98" wc static constraint — sizing this duct requires a mechanical engineer to account for duct length, fittings, and terminal conditions. The unit draws 61 full-load amps at 460V 3-phase; the dedicated circuit must be sized accordingly by a licensed industrial electrician. Reactivation exhaust must not be returned to the conditioned space under any configuration — it carries the full extracted moisture load and will negate the dehumidification output if recirculated.
| Model | MP-2700 / MiniPAC |
|---|---|
| Brand | Bry-Air |
| Type | Desiccant (rotary wheel, no compressor) |
| Process CFM | 2,700 CFM |
| Process External Static | 1.26" wc (32 mm) |
| Reactivation CFM | 840 CFM |
| Reactivation External Static | 0.98" wc (25 mm) |
| Heater Bank | 42 kW with SSR control |
| Voltage | 460V / 3-phase / 60Hz |
| Full Load Amps | 61 A |
| Process Motor | 3 HP / 2.2 kW |
| Reactivation Motor | 1.5 HP / 1.1 kW |
| Unit Dimensions (L × W × H) | 1,227 × 1,156 × 830 mm |
| Process Inlet Duct | 577 × 267 mm |
| Reactivation Outlet Collar | Ø 197 mm |
| Rotor | Water-washable, stainless steel flange, edge-hardened media |
| Controls | Touch-screen PLC with MODBUS RS485 |
| Mounting Options | Floor, wall, or duct-inline |
| Safety Systems | Independent pressure switches, safety thermostat, reactivation cooldown, SSR heater control, electrical interlocks |