Infrared Thermometer Pen with True D:S Laser Guide
Simply press the button and aim the laser Circle guide at the target to scan temperature, release to hold. Results immediately appear in ºC or ºF on the backlit LCD and are automatically held for 27 seconds after the trigger is released. The laser Circle corresponds precisely to IR pen’s 6:1 distance to spot ratio.
Also features min-max, hold and Auto power off. Rugged and ergonomically designed this Infrared thermometer comes complete with one AA battery providing at least 10,000 measurements. The LCD indicates battery status.
- Laser circle indicates the precise area measured
- 6:1 distance to spot ratio, measures up to 932ºF (500ºC)
- Temperature:range-33°C to 500°C -27°F to 932°F | resolution -9.9 to 199.9°C 0.1°C/F | accuracy -9.9 to 199.9°C 0.1°C/F
- Emissivity: 0.95 fixed
Weight: 2 ½ oz (74 g)

*Certification Option
Specifications
| Range | Resolution | Accuracy |
|---|---|---|
| -27 to 932°F -33 to 500°C |
-9.9 to 99.9°C/°F: 0.1°C/°F Above 100°C or below -10°C/°F: 1°C/°F | ±2% of reading or ±2ºC whichever is greater |
| Emissivity | 0.95 fixed | |
| Distance to Spot Size Ratio | 6:1 | |
Downloads
Comparison Chart
Compare Sper Infrared Thermometers
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
|---|---|---|---|---|---|---|---|---|---|
| Model Number | 800100 | 800106 | 800109 | 800111 | 800112 | 800115 | 800130 | 800131 | 800132C |
| Description | IR Thermometer LED Pen | Advanced IR Thermometer Gun 12:1 | IRPen True D:S Laser Guide | IR Thermometer w/ Dew Point 20:1 | Basic IR Thermometer 12:1 | Food Safety Thermometer w/ IR | IR Thermometer 12:1 Calibratable | IR High Temp Thermometer 12:1 | Dual Use IR Thermometer - Sper Certified |
| Range | -27 to 482°F (-33 to 500°C) | -25 to 1400°F (-32 to 760°C) | -27 to 932°F (-33 to 500°C) | -58 to 482°F (-50 to 250°C) | -58 to 932°F (-50 to 500°C) | -58 to 986°F (-50 to 530°C) | -58 to 986°F (-50 to 530°C) | -0°C~950°C (-58°F~1742°F) | 32°C~43°C (89.6°F~109.4°F) |
| Emissivity | 0.95 Fixed | Adjustable 0.1 - 1.0 | 0.95 Fixed | 0.95 Fixed | Adjustable 0.1–1.0 (0.95 Default) | Adjustable 0.1–1.0 | Adjustable 0.1–1.0 (0.95 Preset) | 0.1–1.0 Adjustable (0.95 Preset) | 0.99 Fixed |
| Distance to Spot (D:S) | 1:1 | 12:1 | 6:1 | 20:1 | 12:1 | 4:1 | 12:1 | 12:1 | N/A |
| Resolution | 0.1°F/0.1°C when under 200°C, 1°F/1°C when over 200°C | 0.1°C | -9.9 to 99.9°C/°F: 0.1°C/°F Above 100°C or below -100°C/°F: 1°C/°F | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C (0.1°F) |
| Accuracy | ±2% or 2°C, whichever is greater | ±3.0°C (±5°F) from -32~20°C; ±2.0°C (±3°F) from 20~100°C; Above 100°C ±2% |
±2.0% of reading or ±2.0°C whichever is greater | ±2% of reading or ±2°C whichever is greater | -50°C~0°C: ±2.0°F +0.1°C/°C; 0°C~500°C: ±2.0°F or ±2%; 32°F~932°F: ±4.0°F or ±2% |
±5.4°F (3°C) from 40 to 20°C; ±1.8°F (1°C) for all other temperatures | 0~380°C: ±1.5°C or ±1.5%; 50~0°C: ±3°C whichever is greater |
0°C~950°C: ±1.5°C or ±1.5%; -50°C~0°C: ±3°C whichever is greater |
'0℃~31.9℃ (32℉-89.4℉ ): ±2.0℃(±3.6℉) 32℃~34.9℃(89.6℉~94.8℉): ±0.3℃(±0.5℉) 35℃~42.0℃(95℉~107.6℉): ±0.2℃(±0.4℉) 42.1℃~43.0℃(107.8℉~109.4℉): ±0.3℃(±0.5℉) 43.1℃~100℃(109.6℉~212℉): ±2.0℃(±3.6℉) |
| Hold | √ | √ | √ | √ | √ | √ | √ | √ | |
| Backlit LCD | √ | √ | √ | √ | √ | √ | √ | √ | √ |
| Laser Guide | √ | √ | √ | √ | √ | √ | √ | ||
| Min/Max | √ | √ | √ | √ | √ | ||||
| Audible Alarms | √ | √ | √ | √ | √ | √ | √ | ||
| Thermocouple | √ | ||||||||
| Memory | √ | √ | √ | ||||||
| Penetration Probe | √ | ||||||||
| Ambient Air Temperature | √ | ||||||||
| Humidity | √ | ||||||||
| Dew Point | √ | ||||||||
| Peak | √ | ||||||||
| Battery Type | (1) AAA / 2 LR44 | 9V | (1) AAA | 9V | (2) AAA | (2) AAA | (2) AAA | 9V | (2) AAA |